SIMATIC S7-1500 Analog input module, AI 8xU/I/R/RTD BA, 16 bitresolution, Accuracy 0.5%, 8 channels in groups of 8; Common modevoltage 4 V DC, Diagnostics; Hardware interrupts; Delivery includinginfeed element, shield bracket and shield terminal: Front connector(screw terminals or push-in) to be ordered separately
General informationProduct type designationHW functional statusFirmware version● FW update possibleProduct function● I&M data● Prioritized startupEngineering with● STEP 7 TIA Portal configurable/integrated as ofversion● STEP 7 configurable/integrated as of version● PROFIBUS as of GSD version/GSD revision● PROFINET as of GSD version/GSD revisionOperating mode● Oversampling● MSINoYesV15.1 / V16V5.5 SP3 / -V1.0 / V5.1V2.3 / -Yes; I&M0 to I&M3NoAI 8xU/I/R/RTD BAFS01V1.0.0YesCiR – Configuration in RUN6ES7531-7QF00-0AB0Page 1/6
04/16/2020
Subject to change without notice
© Copyright Siemens
Reparameterization possible in RUNCalibration possible in RUNYesNoPowerPower available from the backplane bus0.85 WPower lossPower loss, typ.0.9 WAnalog inputsNumber of analog inputs● For current measurement● For voltage measurement● For resistance/resistance thermometermeasurementpermissible input voltage for voltage input(destruction limit), max.permissible input current for current input (destructionlimit), max.Technical unit for temperature measurementadjustableInput ranges (rated values), voltages● 0 to +5 V● 0 to +10 V● 1 V to 5 V— Input resistance (1 V to 5 V)● -1 V to +1 V— Input resistance (-1 V to +1 V)● -10 V to +10 V— Input resistance (-10 V to +10 V)● -2.5 V to +2.5 V● -25 mV to +25 mV● -250 mV to +250 mV● -5 V to +5 V— Input resistance (-5 V to +5 V)● -50 mV to +50 mV— Input resistance (-50 mV to +50 mV)● -500 mV to +500 mV— Input resistance (-500 mV to +500 mV)● -80 mV to +80 mVInput ranges (rated values), currents● 0 to 10 mA● 0 to 20 mA— Input resistance (0 to 20 mA)NoYes25 Ω; Plus approx. 42 ohms for overvoltage protection by PTCNoNoYes10 MΩYes10 MΩYes10 MΩNoNoNoYes10 MΩYes10 MΩYes10 MΩNo888812 V; 12 V continuous, 30 V for max. 1 s40 mAYes; °C/°F/K6ES7531-7QF00-0AB0Page 2/6
04/16/2020
Subject to change without notice
© Copyright Siemens
● -20 mA to +20 mA— Input resistance (-20 mA to +20 mA)● 4 mA to 20 mA— Input resistance (4 mA to 20 mA)Input ranges (rated values), thermocouples● Type B● Type C● Type E● Type J● Type K● Type L● Type N● Type R● Type S● Type T● Type U● Type TXK/TXK(L) to GOSTInput ranges (rated values), resistance thermometer● Cu 10● Cu 10 according to GOST● Cu 50● Cu 50 according to GOST● Cu 100● Cu 100 according to GOST● Ni 10● Ni 10 according to GOST● Ni 100— Input resistance (Ni 100)● Ni 100 according to GOST● Ni 1000— Input resistance (Ni 1000)● Ni 1000 according to GOST● LG-Ni 1000— Input resistance (LG-Ni 1000)● Ni 120● Ni 120 according to GOST● Ni 200● Ni 200 according to GOST● Ni 500● Ni 500 according to GOST● Pt 10Yes25 Ω; Plus approx. 42 ohms for overvoltage protection by PTCYes25 Ω; Plus approx. 42 ohms for overvoltage protection by PTCNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoYes; Standard/climate10 MΩNoYes; Standard/climate10 MΩNoYes; Standard/climate10 MΩNoNoNoNoNoNoNo6ES7531-7QF00-0AB0Page 3/6
04/16/2020
Subject to change without notice
© Copyright Siemens
● Pt 10 according to GOST● Pt 50● Pt 50 according to GOST● Pt 100— Input resistance (Pt 100)● Pt 100 according to GOST● Pt 1000— Input resistance (Pt 1000)● Pt 1000 according to GOST● Pt 200● Pt 200 according to GOST● Pt 500● Pt 500 according to GOSTInput ranges (rated values), resistors● 0 to 150 ohms● 0 to 300 ohms● 0 to 600 ohms— Input resistance (0 to 600 ohms)● 0 to 3000 ohms● 0 to 6000 ohms— Input resistance (0 to 6000 ohms)● PTC— Input resistance (PTC)Cable length● shielded, max.NoNoNoYes; Standard/climate10 MΩNoYes; Standard/climate10 MΩNoNoNoNoNoNoNoYes10 MΩNoYes10 MΩYes10 MΩ200 m; 50 m at 50 mVAnalog value generation for the inputsMeasurement principleIntegration and conversion time/resolution per channel● Resolution with overrange (bit including sign),max.● Integration time, parameterizable● Integration time (ms)● Basic conversion time, including integrationtime (ms)— additional conversion time for wire-breakmonitoring— additional conversion time for resistancemeasurement● Interference voltage suppression forinterference frequency f1 in HzSmoothing of measured values● parameterizableYes16 bitYes2,5 / 16,67 / 20 / 100 ms10 / 24 / 27 / 107 ms4 ms (to be considered in R/RTD/U 1 to 5 V measurement)8 ms400 / 60 / 50 / 10 Hzintegrating6ES7531-7QF00-0AB0Page 4/6
04/16/2020
Subject to change without notice
© Copyright Siemens
● Step: None● Step: low● Step: Medium● Step: HighYesYesYesYesEncoderConnection of signal encoders● for voltage measurement● for current measurement as 2-wire transducer● for current measurement as 4-wire transducer● for resistance measurement with two-wireconnection● for resistance measurement with three-wireconnectionYesYes; with external supplyYesYes; Only for PTCYes; All measuring ranges except PTC; internal compensation ofthe cable resistancesErrors/accuraciesLinearity error (relative to input range), (+/-)Temperature error (relative to input range), (+/-)Crosstalk between the inputs, max.Repeat accuracy in steady state at 25 °C (relative toinput range), (+/-)Operational error limit in overall temperature range● Voltage, relative to input range, (+/-)● Current, relative to input range, (+/-)● Resistance, relative to input range, (+/-)● Resistance thermometer, relative to inputrange, (+/-)Basic error limit (operational limit at 25 °C)● Voltage, relative to input range, (+/-)● Current, relative to input range, (+/-)● Resistance, relative to input range, (+/-)● Resistance thermometer, relative to inputrange, (+/-)0.3 %0.3 %0.3 %Ptxxx Standard: ±1.0 K, Ptxxx Climate: ±0.5 K, Nixxx Standard:±0.5 K, Nixxx Climate: ±0.5 K0.5 %0.5 %0.5 %Ptxxx Standard: ±1.2 K, Ptxxx Climate: ±0.8 K, Nixxx Standard:±0.8 K, Nixxx Climate: ±0.8 K0.1 %0.006 %/K-50 dB0.1 %Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency● Series mode interference (peak value ofinterference < rated value of input range), min.● Common mode voltage, max.● Common mode interference, min.40 dB4 V60 dBInterrupts/diagnostics/status informationDiagnostics functionAlarms● Diagnostic alarm● Limit value alarmDiagnostic messagesYesYes; two upper and two lower limit values in each caseYes6ES7531-7QF00-0AB0Page 5/6
04/16/2020
Subject to change without notice
© Copyright Siemens
● Monitoring the supply voltage● Wire-break● Short-circuit● Group error● Overflow/underflowDiagnostics indication LED● RUN LED● ERROR LED● MAINT LED● Monitoring of the supply voltage (PWR-LED)● Channel status display● for channel diagnostics● for module diagnosticsNoYes; Only for 1 ... 5 V, 4 ... 20 mA, R, and RTDNoNoYesYes; green LEDYes; red LEDNoNoYes; green LEDYes; red LEDYes; red LEDPotential separationPotential separation channels● between the channels● between the channels, in groups of● between the channels and backplane busNo8YesIsolationIsolation tested with707 V DC (type test)Ambient conditionsAmbient temperature during operation● horizontal installation, min.● horizontal installation, max.● vertical installation, min.● vertical installation, max.Altitude during operation relating to sea level● Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, seemanual0 °C60 °C0 °C40 °CDimensionsWidthHeightDepth35 mm147 mm129 mmWeightsWeight, approx.last modified:250 g04/15/20206ES7531-7QF00-0AB0Page 6/6
04/16/2020
Subject to change without notice
© Copyright Siemens