量计的流量系数测定实验数据以及处

流量计两端序号流量流速u

(m*3/h)压差 ΔP(kPa) (m/s)

4.112.10.40134.922.70.5167196.633.50.6698218.944.20.80378611.9550.95688814.165.51.05257616.5761.14826519.486.51.243922.4971.339325.6107.51.435331291181.5310232.8128.51.62670936.51391.722398

Red19714.87

25347.6932858.1139429.7446940.1651634.1856328.1961022.2165716.2370410.2475104.2679798.2884492.29

C0.76930.7617410.850820.8792170.9051870.9147340.9224670.9216250.9236670.9257270.92770.926880.930331

lgRed4.2947944.4039384.51634.5958244.671.7129374.75072.78884.8176734.84763.87566.9019944.926817

lgC-0.18863-0.11819-0.07016-0.0559-0.04326-0.03871-0.03505-0.035-0.03448-0.03352-0.03257-0.03298-0.03136

流量计的流量系数测定实验数据以及处理10.950.90.850.80.750.70.650.60.550.502000040000Red6000080000100000C流量计的流量系数测定实验数据以及处理0-0.024.2-0.04-0.06-0.08-0.1-0.12-0.14-0.1.44..85lgC-0.16-0.18-0.2lgRed